ARCHETYPE Visual acuity (openEHR-EHR-OBSERVATION.visual_acuity.v0)

ARCHETYPE IDopenEHR-EHR-OBSERVATION.visual_acuity.v0
ConceptVisual acuity
DescriptionVisual acuity is a measure of the spatial resolution of the visual processing system.
UseUse to record the results of measurement of visual acuity, for both near and distance testing. The 'Clinical Description' data element can be used to record simple narrative summary or as a means to integrate legacy data. Detailed, structured visual acuity results are preferred and are generally recorded for each eye in turn. Visual acuity may be recorded using a number of different notation formats e.g. Snellen, logMar, EDTRS etc. In some settings the visual acuity result, originally captured using one of the standard notations, is converted to a 'Derived Score' capable of algorithmic conversion to the other notations., with details of the original notation and algorithm employed recorded as part of protocol. Where visual acuity is recorded using coded terms such as 'Visual Acuity 6/6' or 'Jaeger score N1', the 'Clinical Interpretation' element should be used, allowing the result to be captured for each eye. 'Overall Interpretation' should be used where the interpretation applies to both eyes or the test result as a whole. The 'Absent Test Result' element may be used to record circumstances where a test could not be performed or completed. Further details may be recorded under 'Confounding Factors' or 'Additional Comment'. When performing visual acuity testing it is customary to record a series of tests sharing a common charting methodology but with different phases of corrective refraction e.g. Unaided, Usual correction, Best corrected visual acuity etc. Each of these phases should be recorded using a separate Entry record, with the name of the test phase carried in 'Test Name'. Further specific details of the exact correction applied (which may involve applying multiple refractions) may be captured in 'Refractive Correction' and 'Refraction Details' the latter making use of separate Cluster archetypes, one for each eye.
MisuseWhere details of methodology carried under protocol change between phases of the visual acuity test, a new Entry must be created at run-time.
PurposeFor recording the results of both near and distance visual acuity testing, normally measured by testing the subject's ability to read a standard test pattern at a defined distance.
ReferencesVisual Acuity [Internet]. Wikipedia. Available from: http://en.wikipedia.org/wiki/Visual_acuity

Aylward W [Internet].Coding Visual Acuity, openEyes Project;2012.Available from http://www.openeyes.org.uk/documents/OpenEyes%20Coding%20Visual%20Acuity.pdf

IHE Eye Care Domain. General Eye Evaluation (GEE) [Internet]. IHE; 2012. Available from: http://www.ihe.net/Technical_Framework/upload/IHE_EyeCare_Supp_GEE_Rev1-1_TI_2012-06-29.pdf

Royal College of Opthalmologists. Cataract National Dataset for Adults [Internet]. 2011. Available from: http://www.rcophth.ac.uk/page.asp?section=583&sectionTitle=Cataract+National+Data+Set+for+Adults

Laidlaw D a. H, Tailor V, Shah N, Atamian S, Harcourt C. Validation of a computerised logMAR visual acuity measurement system (COMPlog): comparison with ETDRS and the electronic ETDRS testing algorithm in adults and amblyopic children. Br J Ophthalmol [Internet]. 2008 Feb 1 [cited 2012 Sep 26];92(2):241–4. Available from: http://bjo.bmj.com/content/92/2/241

CfH, UK. Do Once & Share - Glaucoma [Internet]. [cited 2012 Sep 26]. Available from: http://www.doasglaucoma.org/

DICOM Supplement 30 [Internet]. [cited 2012 Sep 26]. Available from: http://medical.nema.org/

Chiang MF, Boland MV, Brewer A, Epley KD, Horton MB, Lim MC, et al. Special Requirements for Electronic Health Record Systems in Ophthalmology. Ophthalmology [Internet]. 2011 Aug [cited 2012 Sep 26];118(8):1681–7. Available from: http://www.aaojournal.org/article/S0161-6420(11)00374-5/abstract

Practical Ophthalmology: A Manual for Beginning Residents, 6th Edition [Paperback]
American Academy Of Ophthalmology (Author), Fred M. Wilson II (Editor), MD (Editor)
Copyright© Nasjonal IKT HF
AuthorsForfatternavn: Ian McNicoll
Organisasjon: Ocean Informatics, UK
E-post: ian.mcnicoll@oceaninformatics.com
Opprinnelig skrevet dato: 2012-07-18
Other Details LanguageForfatternavn: Ian McNicoll
Organisasjon: Ocean Informatics, UK
E-post: ian.mcnicoll@oceaninformatics.com
Opprinnelig skrevet dato: 2012-07-18
OtherDetails Language Independent{licence=This work is licensed under the Creative Commons Attribution-ShareAlike 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/4.0/., custodian_organisation=Nasjonal IKT, references=Visual Acuity [Internet]. Wikipedia. Available from: http://en.wikipedia.org/wiki/Visual_acuity Aylward W [Internet].Coding Visual Acuity, openEyes Project;2012.Available from http://www.openeyes.org.uk/documents/OpenEyes%20Coding%20Visual%20Acuity.pdf IHE Eye Care Domain. General Eye Evaluation (GEE) [Internet]. IHE; 2012. Available from: http://www.ihe.net/Technical_Framework/upload/IHE_EyeCare_Supp_GEE_Rev1-1_TI_2012-06-29.pdf Royal College of Opthalmologists. Cataract National Dataset for Adults [Internet]. 2011. Available from: http://www.rcophth.ac.uk/page.asp?section=583§ionTitle=Cataract+National+Data+Set+for+Adults Laidlaw D a. H, Tailor V, Shah N, Atamian S, Harcourt C. Validation of a computerised logMAR visual acuity measurement system (COMPlog): comparison with ETDRS and the electronic ETDRS testing algorithm in adults and amblyopic children. Br J Ophthalmol [Internet]. 2008 Feb 1 [cited 2012 Sep 26];92(2):241–4. Available from: http://bjo.bmj.com/content/92/2/241 CfH, UK. Do Once & Share - Glaucoma [Internet]. [cited 2012 Sep 26]. Available from: http://www.doasglaucoma.org/ DICOM Supplement 30 [Internet]. [cited 2012 Sep 26]. Available from: http://medical.nema.org/ Chiang MF, Boland MV, Brewer A, Epley KD, Horton MB, Lim MC, et al. Special Requirements for Electronic Health Record Systems in Ophthalmology. Ophthalmology [Internet]. 2011 Aug [cited 2012 Sep 26];118(8):1681–7. Available from: http://www.aaojournal.org/article/S0161-6420(11)00374-5/abstract Practical Ophthalmology: A Manual for Beginning Residents, 6th Edition [Paperback] American Academy Of Ophthalmology (Author), Fred M. Wilson II (Editor), MD (Editor), original_namespace=no.nasjonalikt, original_publisher=Nasjonal IKT, custodian_namespace=no.nasjonalikt, MD5-CAM-1.0.1=40257D2E6706FAD3DF8F21EE33CF824F, build_uid=237162e3-cc3e-44e4-b6e4-d61bc24e2283, revision=0.0.1-alpha}
Keywordseye, sight, vision, ophthalmic, visual, refraction
Lifecyclein_development
UIDdcec95df-69e2-47c6-8bdf-9710738f2f07
Language useden
Citeable Identifier1078.36.807
Revision Number0.0.1-alpha
AllArchetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Visual acuity is a measure of the spatial resolution of the visual processing system., archetypeConceptComment=null, otherContributors=Bill Aylward, openEyes Project, UK
Gustavo Bacelar-Silva, Brazil (Editor)
Stephen Chu, NeHTA, Australia
Alistair Laidlaw, Guys and St Thomas NHS Trust, UK
Heather Leslie, Ocean Informatics, Australia
Gustavo M Bacelar-Silva, Brazil
Mike Mair, Timaru Eye Clinic, New Zealand
Ian McNicoll, Ocean Informatics, United Kingdom (Editor), originalLanguage=en, translators=, subjectOfData=ubegrenset, archetypeTranslationTree=null, topLevelToAshis={context=[], state=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/state[at0041]/items[at0112], code=at0112, itemType=ELEMENT, level=4, text=Confounding Factors, description=Patient circumstances which affect interpretation of the result. Often termed 'reliability' in opthalmological documentation., comment=Examples: 'Patient was confused', 'Low light conditions'., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Valgfritt, gjentagende, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/state[at0041]/items[at0042], code=at0042, itemType=ELEMENT, level=4, text=Refractive Correction, description=The specific type(s) of refractive correction applied when measuring visual acuity., comment=Examples: 'No correction : unaided', 'Pinhole'., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Valgfritt, gjentagende, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Spectacles [The subject's vision was corrected by spectacles.]
    [SNOMED-CT::50121007] (Eye glasses, device (physical object))
  • Contact lenses [The subject's vision was corrected by contact lenses.]
    [SNOMED-CT::57368009] (Contact lenses, device (physical object))
  • Pinhole [The subject's vision was corrected by use of a pinhole.]
  • Autorefraction [The subject's vision was corrected by autorefraction.]
  • Retinoscopy [The subject's vision was corrected by retinoscopy.]
    [SNOMED-CT::397524001] (Retinoscopy (procedure))
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/state[at0041]/items[at0080], code=at0080, itemType=SLOT, level=4, text=Refraction Details, description=Details of the refraction applied to each eye., comment=null, uncommonOntologyItems=null, occurencesFormal=0..2, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Inkluder:
openEHR-EHR-CLUSTER.refraction_details.v1 og spesialiseringer, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/state[at0041]/items[at0124], code=at0124, itemType=SLOT, level=4, text=Pupillary State, description=Details of the state of the pupil on examination., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Inkluder:
openEHR-EHR-CLUSTER.exam_pupils.v1 og spesialiseringer, extendedValues=null]], capabilities=[], contacts=[], details=[], identities=[], description=[], events=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134], code=at0134, itemType=POINT_EVENT, level=2, text=Any event, description=Default, unspecified point in time or interval event which may be explicitly defined in a template or at run-time., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Valgfritt, gjentagende, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=POINT_EVENT, bindings=null, values=null, extendedValues=null]], source=[], protocol=[ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0081], code=at0081, itemType=ELEMENT, level=2, text=Testing Distance, description=The distance at which the subject's visual acuity was measured., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=[SNOMED-CT::252124009 | Test distance (observable entity)], values=Egenskap: Length
Enheter:
  • >=0.0 ft
    Begrens antall desimaler: 1
  • >=0.0 m
    Begrens antall desimaler: 1
  • >=0.0 cm
    Begrens antall desimaler: 1
  • >=0.0 in
    Begrens antall desimaler: 1
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0023], code=at0023, itemType=ELEMENT, level=2, text=Chart Method, description=The charting method used to measure visual acuity., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • logMar chart [A logMar chart was used to measure distance visual acuity.]
  • Snellen chart [A Snellen chart was used to measure distance visual acuity.]
    [SNOMED-CT::400913005] (Snellen chart (physical object))
  • ETDRS chart [An ETDRS chart was used to measure distance visual acuity.]
    [SNOMED-CT::400914004] (Early Treatment of Diabetic Retinopathy Study (ETDRS) visual acuity chart (physical object))
  • Picture chart [A picture chart was used to measure distance visual acuity.]
  • Reduced logMar [A Reduced logMar chart was used to measure near visual acuity.]
  • Reduced Snellen [A Reduced Snellen chart was used to measure near visual acuity.]
    [SNOMED-CT::422673001] (Snellen visual acuity (observable entity))
  • Faculty of Ophthalmologists 'N' Score [Faculty of Ophthalmologists 'N' Score chart was used to measure near visual acuity.]
  • Jaeger 'J' Score [A Jaeger 'J' Score chart was used to measure near visual acuity.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0021], code=at0021, itemType=ELEMENT, level=2, text=Chart Optotype, description=The style of chart optotype used to assess visual acuity., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Letter [A letter optotype was used to measure distance visual acuity.]
  • Orientation [An orientation optotype was used to measure distance visual acuity.]
  • Picture [A picture optotype was used to measure distance visual acuity.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0022], code=at0022, itemType=ELEMENT, level=2, text=Chart Scoring Algorithm, description=The alogrithm used to determine the score., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Single letter [A single letter algorithm was used to derive the visual acuity score.]
  • Whole line [A whole line algorithm was used to derive the visual acuity score.]
  • Last line single letter [A last line single letter algorithm was used to derive the visual acuity score.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0025], code=at0025, itemType=SLOT, level=2, text=Measurement Device Details, description=Details of the device used to measure visual acuity., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Inkluder:
openEHR-EHR-CLUSTER.device.v1 og spesialiseringer, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0092], code=at0092, itemType=ELEMENT, level=2, text=Derived Score Original Notation, description=The original visual acuity result notation from which the Derived Score was calculated., comment=When the visual acuity result is recorded using a Derived Score, this element can be used to record the original notation format, so that it can be displayed using the original notation. , uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • US Snellen [The distance test result, recorded as Snellen visual acuity expressed in feet, where 20/20 is regarded as normal.]
    [SNOMED-CT::422673001] (Snellen visual acuity (observable entity))
  • Metric Snellen [The distance test result, recorded in Snellen format expressed in metres, where 6/6 is regarded as normal.]
    [SNOMED-CT::422673001] (Snellen visual acuity (observable entity))
  • Decimal Snellen [The distance test result,recorded as Sn ellen visual acuity expressed as a decimal ratio, where 1.0 is regarded as normal.]
    [SNOMED-CT::422673001] (Snellen visual acuity (observable entity))
  • ETDRS Letters [Visual acuity expressed using ETDRS Letters format, with a value of 100 regarded as normal.]
  • Low Vision Score [Graded scale used when patient has low levels of visual acuity.]
  • logMar [The test result, recorded as logMar visual acuity, where a value of 0 is regarded as normal.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0117], code=at0117, itemType=ELEMENT, level=2, text=Derived Score Algorithm, description=Details of the algorithm used to calculate a derived score., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null]], items=[], credentials=[], ism_transition=[], data=[ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0138], code=at0138, itemType=ELEMENT, level=4, text=Test Name, description=The name of the exact visual acuity test performed. This generally represents a broad category of applied refraction. Specific refraction details can be described using 'Refractive Correction'., comment=Details of the exact correction applied, or where multiple corrections should be captured via 'Refractive Correction'., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=Mulige datatyper:
  •  Kodet tekst
    • Pinhole visual acuity [The test is performed with pinhole refraction applied.]
    • Usual corrected visual acuity [The test is performed with the patient's usual refractive correction i.e spectacles or contact lenses.]
    • Best corrected visual acuity [The test is performed with the patient's optimal refractive correction.]
    • Unaided visual acuity [The test was performed without visual aid.]
  •  Fri eller kodet tekst
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0039], code=at0039, itemType=ELEMENT, level=4, text=Description, description=An overall narrative description of the visual acuity test result., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=[SNOMED-CT::117364006 | Narrative value (qualifier value)], values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053], code=at0053, itemType=CLUSTER, level=4, text=Per Eye, description=Details of the visual field test result for each eye., comment=null, uncommonOntologyItems=null, occurencesFormal=0..2, occurencesText=Valgfritt, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0007], code=at0007, itemType=ELEMENT, level=5, text=Eye Examined, description=The eye which is being examined., comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Obligatorisk, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Left eye [The test result refers to the visual acuity of the left eye only.]
    [SNOMED-CT::362503005] (Entire left eye (body structure))
  • Right eye [The test result refers to the visual acuity of the right eye only.]
    [SNOMED-CT::362502000] (Entire right eye (body structure))
  • Both eyes simultaneously [Both eyes were examined simultaneously.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0055], code=at0055, itemType=ELEMENT, level=5, text=Absent Result, description=Details of a test result which could not be recorded., comment=Details of reasons for an absent test result can be described in Additional Comment or Confounding Factors., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=Mulige datatyper:
  •  Kodet tekst
    • Not performed [The visual acuity test was never performed.]
    • Not completed [The visual acuity test was started but could not be completed.]
  •  Fri eller kodet tekst
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0028], code=at0028, itemType=CLUSTER, level=5, text=Notation, description=Details of a visual acuity result recorded using one of the result notation formats., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=1..*, cardinalityText=, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0028]/items[at0056], code=at0056, itemType=ELEMENT, level=6, text=Metric Snellen, description=The distance test result, recorded in Snellen format expressed in metres, where 6/6 is regarded as normal., comment=Examples: '6/6, '6/12', '6/5', uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_PROPORTION, bindings=[SNOMED-CT::422673001 | Snellen visual acuity (observable entity)], values=
  • Tallforhold
Teller: 1.0..6.0
Nevner: 4.0..60.0
Integral
Antatt verdi: false
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0028]/items[at0009], code=at0009, itemType=ELEMENT, level=6, text=US Snellen, description=The distance test result, recorded as Snellen visual acuity expressed in feet, where 20/20 is regarded as normal., comment=Examples: '20/20' , '20/40', '20/18', uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_PROPORTION, bindings=[SNOMED-CT::422673001 | Snellen visual acuity (observable entity)], values=
  • Tallforhold
Teller: 3.0..20.0
Nevner: 2.0..200.0
Integral
Antatt verdi: false
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0028]/items[at0057], code=at0057, itemType=ELEMENT, level=6, text=Decimal Snellen, description=The distance test result,recorded as Sn ellen visual acuity expressed as a decimal ratio, where 1.0 is regarded as normal., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_PROPORTION, bindings=[SNOMED-CT::422673001 | Snellen visual acuity (observable entity)], values=
  • Fraksjon
Teller: 0.0..2.0
Integral
Antatt verdi: false
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0028]/items[at0011], code=at0011, itemType=ELEMENT, level=6, text=ETDRS Letters, description=Visual acuity expressed using ETDRS Letters format, with a value of 100 regarded as normal., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_COUNT, bindings=null, values=min: >=1; max: <=120

, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0028]/items[at0046], code=at0046, itemType=ELEMENT, level=6, text=logMar, description=The test result, recorded as logMar visual acuity, where a value of 0 is regarded as normal., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=null, values=Egenskap: Qualified real
Enheter:
  • -0.5..2.0
    Begrens antall desimaler: 1
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0028]/items[at0015], code=at0015, itemType=ELEMENT, level=6, text=Low Vision Score, description=Graded scale used when patient has low levels of visual acuity., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_ORDINAL, bindings=null, values=1: NPL - No perception of light [The subject has no perception of light.]
2: PL - Perception of light [The subject can perceive light.]
3: HM - Hand movement [The subject can perceive hand movement.]
4: CF - Count fingers [The subject can count fingers.]
[SNOMED-CT::422256009 | Counts fingers - distance vision (finding)]

, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0059], code=at0059, itemType=ELEMENT, level=5, text=Letter Termination Adjustment, description=A line termination adjustment score applied to the visual acuity result., comment=If the patient can read at least half of the chart line the visual acuity terminatin line is recorded as that line, with the number of letters missed on that line recorded as a negative Letter Termination Adjustment score. If the patient can read less than half of a Visual Acuity line, the previous line is recorded as the Visual Acuity result, with the number of letters seen on the following line recorded as a positive 'Letter Termination Adjustment' score., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_COUNT, bindings=null, values=min: >=-10; max: <=10
<br/>Antatt verdi0
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0010], code=at0010, itemType=ELEMENT, level=5, text=Derived Score, description=Visual acuity expressed as an integer score which is calculated from one or more of the other result notation formats. The original notation should be captured using 'Derived Score Original Notation' format'., comment=Details of the algorithm used and original result format may be recorded under 'Derived Score Methodology'., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_COUNT, bindings=null, values=min: >=0

, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0053]/items[at0066], code=at0066, itemType=ELEMENT, level=5, text=Interpretation, description=The test result expressed as a qualitative term, normally coded., comment=Example: 'Visual Acuity 20/20' or 'Jaeger 'J2' score'., uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Valgfritt, gjentagende, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=[SNOMED-CT::363983007 | Visual acuity (observable entity)], values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0054], code=at0054, itemType=ELEMENT, level=4, text=Overall Interpretation, description=A term, commonly coded, expressing an overall interpretation of the visual acuity test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Valgfritt, gjentagende, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=[SNOMED-CT::271922009 | Visual test interpretation (observable entity)], values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/data[at0001]/events[at0134]/data[at0003]/items[at0040], code=at0040, itemType=ELEMENT, level=4, text=Comment, description=Any additional narrative comment about the visual acuity test., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=[SNOMED-CT::117364006 | Narrative value (qualifier value)], values=, extendedValues=null]], relationships=[], other_participations=[], target=[], content=[], provider=[], activities=[]}, topLevelItems={protocol=ResourceSimplifiedHierarchyItem [path=ROOT_/protocol[at0020], code=at0020, itemType=ITEM_TREE, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Obligatorisk, cardinalityFormal=1..1, cardinalityText=obligatorisk, subCardinalityFormal=0..*, subCardinalityText=Minimum 0 oppføringer, dataType=ITEM_TREE, bindings=null, values=null, extendedValues=null], state=ResourceSimplifiedHierarchyItem [path=ROOT_/data[at0001]/events[at0134]/state[at0041], code=at0041, itemType=ITEM_TREE, level=2, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Obligatorisk, cardinalityFormal=1..1, cardinalityText=obligatorisk, subCardinalityFormal=0..*, subCardinalityText=Minimum 0 oppføringer, dataType=ITEM_TREE, bindings=null, values=null, extendedValues=null], data=ResourceSimplifiedHierarchyItem [path=ROOT_/data[at0001]/events[at0134]/data[at0003], code=at0003, itemType=ITEM_TREE, level=2, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Obligatorisk, cardinalityFormal=1..1, cardinalityText=obligatorisk, subCardinalityFormal=0..*, subCardinalityText=Minimum 0 oppføringer, dataType=ITEM_TREE, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=protocol, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0081], code=at0081, itemType=ELEMENT, level=2, text=Testing Distance, description=The distance at which the subject's visual acuity was measured., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=C_DV_QUANTITY, bindings=[SNOMED-CT::252124009 | Test distance (observable entity)], values=Egenskap: Length
Enheter:
  • >=0.0 ft
    Begrens antall desimaler: 1
  • >=0.0 m
    Begrens antall desimaler: 1
  • >=0.0 cm
    Begrens antall desimaler: 1
  • >=0.0 in
    Begrens antall desimaler: 1
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0023], code=at0023, itemType=ELEMENT, level=2, text=Chart Method, description=The charting method used to measure visual acuity., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • logMar chart [A logMar chart was used to measure distance visual acuity.]
  • Snellen chart [A Snellen chart was used to measure distance visual acuity.]
    [SNOMED-CT::400913005] (Snellen chart (physical object))
  • ETDRS chart [An ETDRS chart was used to measure distance visual acuity.]
    [SNOMED-CT::400914004] (Early Treatment of Diabetic Retinopathy Study (ETDRS) visual acuity chart (physical object))
  • Picture chart [A picture chart was used to measure distance visual acuity.]
  • Reduced logMar [A Reduced logMar chart was used to measure near visual acuity.]
  • Reduced Snellen [A Reduced Snellen chart was used to measure near visual acuity.]
    [SNOMED-CT::422673001] (Snellen visual acuity (observable entity))
  • Faculty of Ophthalmologists 'N' Score [Faculty of Ophthalmologists 'N' Score chart was used to measure near visual acuity.]
  • Jaeger 'J' Score [A Jaeger 'J' Score chart was used to measure near visual acuity.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0021], code=at0021, itemType=ELEMENT, level=2, text=Chart Optotype, description=The style of chart optotype used to assess visual acuity., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Letter [A letter optotype was used to measure distance visual acuity.]
  • Orientation [An orientation optotype was used to measure distance visual acuity.]
  • Picture [A picture optotype was used to measure distance visual acuity.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0022], code=at0022, itemType=ELEMENT, level=2, text=Chart Scoring Algorithm, description=The alogrithm used to determine the score., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • Single letter [A single letter algorithm was used to derive the visual acuity score.]
  • Whole line [A whole line algorithm was used to derive the visual acuity score.]
  • Last line single letter [A last line single letter algorithm was used to derive the visual acuity score.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0025], code=at0025, itemType=SLOT, level=2, text=Measurement Device Details, description=Details of the device used to measure visual acuity., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Inkluder:
openEHR-EHR-CLUSTER.device.v1 og spesialiseringer, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0092], code=at0092, itemType=ELEMENT, level=2, text=Derived Score Original Notation, description=The original visual acuity result notation from which the Derived Score was calculated., comment=When the visual acuity result is recorded using a Derived Score, this element can be used to record the original notation format, so that it can be displayed using the original notation. , uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_CODED_TEXT, bindings=null, values=
  • US Snellen [The distance test result, recorded as Snellen visual acuity expressed in feet, where 20/20 is regarded as normal.]
    [SNOMED-CT::422673001] (Snellen visual acuity (observable entity))
  • Metric Snellen [The distance test result, recorded in Snellen format expressed in metres, where 6/6 is regarded as normal.]
    [SNOMED-CT::422673001] (Snellen visual acuity (observable entity))
  • Decimal Snellen [The distance test result,recorded as Sn ellen visual acuity expressed as a decimal ratio, where 1.0 is regarded as normal.]
    [SNOMED-CT::422673001] (Snellen visual acuity (observable entity))
  • ETDRS Letters [Visual acuity expressed using ETDRS Letters format, with a value of 100 regarded as normal.]
  • Low Vision Score [Graded scale used when patient has low levels of visual acuity.]
  • logMar [The test result, recorded as logMar visual acuity, where a value of 0 is regarded as normal.]
, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/protocol[at0020]/items[at0117], code=at0117, itemType=ELEMENT, level=2, text=Derived Score Algorithm, description=Details of the algorithm used to calculate a derived score., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Valgfritt, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null]