| ARCHETYPE ID | openEHR-EHR-OBSERVATION.visual_field_measurement_draft.v0 |
|---|---|
| Concept | Visual field measurement |
| Description | Results of visual field testing / perimetry. |
| Use | To record the results of visual field testing or perimetry. The 'Clinical Description' data element can be used to record simple narrative summary or as a means to integrate legacy data. Detailed, structured visual acuity results are preferred and are generally recorded for each eye in turn. |
| Misuse | Where the perimetry method or device changes between each eye, a new record Entry should be created at runtime. |
| Purpose | For recording the results of visual field testing or perimetry. |
| References | IHE Eye Care Domain. General Eye Evaluation (GEE) [Internet]. IHE; 2012. Available from: http://www.ihe.net/Technical_Framework/upload/IHE_EyeCare_Supp_GEE_Rev1-1_TI_2012-06-29.pdf Royal College of Opthalmologists. Cataract National Dataset for Adults [Internet]. 2011. Available from: http://www.rcophth.ac.uk/page.asp?section=583§ionTitle=Cataract+National+Data+Set+for+Adults CfH, UK. Do Once & Share - Glaucoma [Internet]. [cited 2012 Sep 26]. Available from: http://www.doasglaucoma.org/ DICOM Supplement 30 [Internet]. [cited 2012 Sep 26]. Available from: http://medical.nema.org/ http://www.slideshare.net/hmirzaeee/glaucoma-hemifield-test Standard Automated Perimetry, EyeWiki, http://eyewiki.aao.org/Standard_Automated_Perimetry |
| Copyright | © Nasjonal IKT HF |
| Authors | Forfatternavn: Ian McNicoll Organisasjon: Ocean Informatics UK E-post: ian.mcnicoll@oceaninformatics.com Opprinnelig skrevet dato: 2012-09-19 |
| Other Details Language | Forfatternavn: Ian McNicoll Organisasjon: Ocean Informatics UK E-post: ian.mcnicoll@oceaninformatics.com Opprinnelig skrevet dato: 2012-09-19 |
| Other Details (Language Independent) |
|
| Keywords | perimetry, ophthalmic, optometry, eye, vision, visual |
| Lifecycle | in_development |
| UID | 021294db-62a1-4404-a6e6-557d7f28e5fc |
| Language used | en |
| Citeable Identifier | 1078.36.1843 |
| Revision Number | 0.0.1-alpha |
| data | |
| Clinical Description | Clinical Description: A term, commonly coded, expressing an overall interpretation of the visual field test. |
| Test Result | Test Result: Details of the visual field test result for each eye. |
| Eye | Eye: The eye which is being examined.
|
| Glaucoma Hemifield Test (GHT) | Glaucoma Hemifield Test (GHT): A coded intepretation of the Glaucoma Hemifield Test (GHT).
|
| Visual Field Index | Visual Field Index: Visual Field Index result.
Integral Antatt verdi: false |
| Mean deviation | Mean deviation: The average of deviation in vusual field across all test areas. Egenskap: Loudness Enheter: -30.0..10.0 dB Begrens antall desimaler: 2 |
| Mean deviation P | Mean deviation P: The P value of the Mean Deviation result.
|
| Pattern Standard deviation | Pattern Standard deviation: Average of non-uniform visual field loss. Egenskap: Loudness Enheter: 0.0..25.0 dB Begrens antall desimaler: 2 |
| Pattern Standard deviation P | Pattern Standard deviation P: The P value of the Pattern Standard deviation result.
|
| Clinical Interpretation | Clinical Interpretation: The test result expressed as a qualitative term, normally coded. |
| Image | Image: A multimedia representaion of the visual field test. image/cgm, image/gif, image/png, image/tiff, image/jpeg |
| Overall Interpretation | Overall Interpretation: A term, commonly coded, expressing an overall interpretation of the visual field test. |
| Additional Comment | Additional Comment: Any additional narrative comment about the visual field test. |
| protocol | |
| Perimetry Method | Perimetry Method: The method used to record the perimetry result.
|
| Device Details | Device Details: Details of the device used to measure visual fields. Inkluder: openEHR-EHR-CLUSTER.device.v1 og spesialiseringer |
| state | |
| Confounding Factors | Confounding Factors: Patient circumstances which may affect interpretation of the result. |
| Refractive correction | Refractive correction: Details of refractive correction applied to each eye. Inkluder: openEHR-EHR-CLUSTER.refraction_ |
| events | |
| Any event | Any event: Any measurement event. |
| Other contributors | Gustavo Bacelar-Silva, Brazil |
| Translators |